DC coupled LVPECL inputs for the transmitter. 50Ω differential lines.
RD+, RD-:
Open-emitter out circuits. DC coupled LVPECL outputs for the receiver. 50Ω differential lines.
SD:
Signal Detect. Normal optical input levels to the receiver result in a logic “1” output, VOH, asserted. Low input optical levels to the receiver result in a fault condition indicated by a logic “0” output VOL, deasserted.
SD is a single-ended LVPECL output and can be terminated with LVPECL techniques via 50 Ω to RX Vcc − 2V.
Alternatively, SD can be loaded with a 180 Ω resistor to RX GND to conserve electrical power with small compromise to signal quality.
If SD output is not used, leave it open-circuited. This SD output can be used to drive a LVPECL input on an upstream circuit, such as, SD input or Loss of Signal-bar. Connect to ground if not needed.